Chapter 3 Technical Information
RFU63x RFID Write/Read Device (UHF)
12 © SICK AG · Germany · All rights reserved · Subject to change without notice 8014335/YUO7/2016-04-04
Mounting
3.2.3 Installing pivot mounting bracket (no. 2061737) on the RFU630
Procedure for attachment on the RFU630:
1. Fasten the angle flange to the RFU630 (supplied are: 4x M6 x 16 mm screws with
A6 washer).
2. Fasten the mounting bracket to the assembly base provided by the customer (supplied
are: 2 x M6 x 16 mm screws with A6 washer). Do not tighten the screws just yet.
3. Fasten the RFU630 together with the mounting bracket to the angle flange (supplied
are: 4x self-locking M6 x 12 mm screws and A6 washers). Do not tighten the screws just
yet.
4. Align RFU630 to the scanning point in two axes.
5. Tighten all screws.
All length measures in mm
Threaded mounting hole
M6, 11 mm deep
M6 x 12 mm,
self-locking
(4 x)
M6 x 16 mm
(6 x)
Mounting bracket
Angle
flange
Pivot mounting
bracket,
complete
95.2
M6
5
5
9.4
9.4
102.8
Ø 10Ø 18
80
90°
Ø 41.5
68
68
90°
60
84
30