7.1.2.1.2 Acyclic data
In addition to the process data, device data (parameters, identification data and diag‐
nostic information) can be transmitted to and from the IO-Link Master.
NOTE
Not all functions available through SOPAS Engineering Tool are also available through
PROFINET. This mainly concerns the use of the Logic Editor.
7.1.2.1.2.1 Start-up records
The following start-up records are used by SIG200 PROFINET.
Submodule
name
Index Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Configuration
Module
(Slot 1, Subslot
1)
8825
(0x227
9)
0 Record major version number (“1”)
1 Record minor version number (“0”)
2 Record minor version number (“0”) GDIA
G
All IO-Link
Device sub‐
modules
(except “Digital
input”, “Digital
output”)
47360
(0xB90
0)
0 Record major version number (“1”)
1 Record minor version number (“0”)
4 0 0 0 0 PCM 0 0
5 Validation and Backup
6 Expected Vendor ID
7
8 Expected Device ID
9
10
11
12 Port cycle time
SIG200 CONFIGURATION 7
8017853/2019-06-06 | SICK O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200
27
Subject to change without notice