Command HTTP
method
Request JSON
body
Response JSON
body
Function
api/Port1BackupLevel, api/
Port2BackupLevel, api/
Port3BackupLevel, api/
Port4BackupLevel
GET - {
"header": {
"status": 0,
"message": "Ok"
},
"data": {
"Port1Backu‐
pLevel": 1
}
Data storage
backup level for
port 1. 1 =
RESTORE,2 =
BACKUP/
RESTORE, 3 =
Disabled
POST
(write)
{
"data": {
"Port1Backu‐
pLevel": 1
}
}
-
api/crown/ac/
GetDiskUsage
POST
(read)
- {
"header": {
"status": 0,
"message": "Ok"
},
"data": {"Byte‐
sUsed":
0.000000,"Capa
city":
2469606195.00
0000}
Returns how
many bytes of the
device’s fileystem
is being used.
The SIG200 has
3.2GB of avail‐
able disk space.
api/crown/ac/GetLinkSta‐
tus
POST
(read)
{ "data": {"Port":
1}}
{
"header": {
"status": 0,
"message": "Ok"
},
"data": {
"Status":
"100MB-Full
Duplex"
}
Returns the link
status of Ethernet
ports (“Port” =1
or 2)
api/crown/ac/GetPortSta‐
tus
POST
(read)
{ "data": {"Port":
1}}
{
"header": {
"status": 0,
"message": "Ok"
},
"data": {
"Status": "OK",
"Pin4Value":
false,
"Pin2Value":
false,
"ConnectedDe‐
vice": "PAC50-
BCD"
}}
Returns the sig‐
nal status and
name of con‐
nected device on
an IO-Link port
(“Port”=1, 2, 3, or
4)