Command HTTP
method
Request JSON
body
Response JSON
body
Function
api/crown/ac/SetPortOut‐
put
POST(w
rite)
{
"data":
{
"Port": 1,
"Value": true
}
}
{
"header": {
"status": 0,
"message": "Ok"
},
"data": {
"Status": "Ok"
}
}
Sets pin 4 to high
(true) or low
(false) according
to the value and
port defined in
the request body.
NOTE
The port owner
needs to be con‐
figured as REST
in order to
change the state
of the digital out‐
put.
api/crown/ac/GetPortCon‐
figuration
POST
(read)
{ "data": {"Port":
1}}
{
"header": {
"status": 0,
"message": "Ok"
},
"data": {
"Status": "OK",
"Pin4Configura‐
tion": "IOLink",
"PortOwner":
"Logic Editor",
"CycleTime": "as
fast as possible",
"IODDFileName":
"none",
"DataStor‐
ageLevel": "Dis‐
abled",
"VendorID": "0",
"DeviceID": "0"
}
Returns the full
port configuration
of an IO-Link port
(“Port”=1, 2, 3, or
4)
api/crown/ac/ReadDataS‐
torage
POST
(read)
{
"data":
{
"Port": 1
}
}
{
"header": {
"status": 0,
"message": "Ok"
},
"data": {
"DS_Data":
"eHCAIRoA1g‐
GAAAAADAAAA‐
gAA‐
GAAAB3QAdGVzd
CBCAAABAk‐
MAAAQAAAACRA
AABAAAAMhRAA
AEAAAQAFI‐
AAAQBAAAAVQAA
AQA="
}
}
Returns data stor‐
age object as a
Base64 coded
string of an IO-
Link port
(“Port”=1, 2, 3, or
4).