Command HTTP
method
Request JSON
body
Response JSON
body
Function
iolink/sickv1/readDevice
(ISDU data)
POST {
"header": {
"portNumber": 0
},
"data": {
"variable":
"V_Application‐
SpecificTag"
}
}
{
"header": {
"status": 0,
"message": "Ok"
},
"data": {
"V_Application‐
SpecificTag":
"*******"
}
}
Returns the
parsed para‐
meter data
of a con‐
nected IO-
Link Device.
portNumber:
0 = port 1, 1
= port 2, 2 =
port 3, 3 =
port 4
variable:
ISDU name
as given by
IODD
data: struc‐
tured para‐
meter data
iolink/sickv1/writeDevice
(ISDU data)
POST {
"header": {
"portNumber": 1
},
"data": {
"V_Application‐
Specific‐
Tag":"ABCD"
}
}
{
"header": {
"status": 0,
"message": "Ok"
}
}
Sets the
parsed para‐
meter data
of a con‐
nected IO-
Link Device.
portNumber:
0 = port 1, 1
= port 2, 2 =
port 3, 3 =
port 4
7 SIG200 CONFIGURATION