EMC
- Immunity
- Emission
- EN 61000-6-2
- EN 61000-6-4
CAUTION
This equipment is not intended for use in resi‐
dential environments and may not provide ade‐
quate protection to radio reception in such
environments.
Shock / shaking EN 60068-2-6, EN 60068-2-27
Electrical data
Power supply 10 ... 30 V DC
Power Supply IO-Link 18 ... 30 V DC
Voltage ripple < 1 %
IO-Link Port output current capability per port 200 mA
PROFINET
PROFINET/IP port 1x10 Nase- / 100 Base-Tx
Cable type according to IEEE 802.3 Min. STP CAT 5 / ST CAT 5e
Data transmission rate 10 / 100 Mbits/s
Max. cable length 100 m
Flow control Half Duplex / Full Duplex (IEEE 802.33x
Pause)
PROFINET features Media Redundancy (MRP),
network diagnostic (MIB/SNMP),
topollogy detection,
port diagnostic (Up/Down),
conneciton diagnostic (connection length mea‐
surement),
I&M0 ... 4,
auto device replacement,
reduction ratio,
openVAS tested
GSD file available (V2.2, V2.32, V2.33, V2.34)
Netload Class II
Conformance Class B
Compliant standard IEEE802.3u (100Base-Tx)
Ethernet
Ethernet interface 2x100 Base-Tx (switched)
Cable type acc. to IEEE 802.3 Min. STP CAT 5 / ST CAT 5e
Data transmission rate 100 Mbits/s
Max. cable length 100 m
Flow control Half Duplex / Full Duplex (IEEE 802.33x
Pause)
Used Ethernet protocols ICMP, TCP, UDP
Open TCP ports 80 (HTTP), 2111/2113/2122 (SOPAS)
Open UDP ports 1900 (UPNP)
TECHNICAL DATA 12
8017853/2019-06-06 | SICK O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200
99