EasyManua.ls Logo

SICK UE 402 - Operating mode selector switch; Key-operated pushbutton for bypass

SICK UE 402
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions Chapter

8 009 874/31-03-03 © SICK AG • Industrial Safety Systems • Germany • All rights reserved
23
   
  
The UE 402 has connections for an operating mode selector switch with up to 6 switch
settings.
If the safety light curtain can be selected on the machine side, this must also be
selected via the operating mode selector switch.
The operating mode selector switch must be a key-operated switch.
Use an operating mode selector switch, that has only the same number of switch settings
that you actually need. This will help you to reduce the likelihood of operating errors.
# @!> ! 
The bypass function may only be activated by a key-operated switch with an automatic
reset and two levels or by two input signals that are independent of each other, e.g. two
positioning switches.
Mount the key-operated pushbutton for bypass in such a way that the hazardous point is
completely visible when the key-operated switch is used.
The key-operated pushbutton for bypass must have potential-free contacts.
When you connect the key-operated pushbutton for bypass to the UE 402, you can only
connect a teach-in key-operated switch directly to the C 4000.
You must configure the switching mode of the key-operated pushbutton for bypass to
comply with the selected switch type (N/C, N/O or N/O, N/O) with the aid of the CDS:
Device symbol C 4000 Host (receiver), context menu Configuration draft, Edit, selection
System, file card General, option Key-operated pushbutton for bypass.
Fig.
9
:
Connection for the
operating mode selector
switch on the UE 402
.
4 
Fig.
10
:
Alternative
connections for the key-
operated pushbutton for
bypass on the UE 402
.
24 V DC
Complimentary
Equivalent

Table of Contents