3 On safety
This chapter deals with your own safety and the safety of the equipment operators.
b
P
lease read this chapter carefully before working with the UE10-3OS or with the
machine protected by the UE10-3OS.
3.1 Skilled persons
The UE10-3OS expansion module must only be installed, commissioned and serviced
b
y qualified safety personnel.
Qualified safety personnel are defined as persons who …
•
have undergone the appropriate technical training and
•
have been instructed by the responsible machine operator in the operation of the
machine and the current valid safety guidelines and
•
have access to the operating instructions of the expansion module and have read
and familiarised themselves with them.
3.2 Field of use for the device
The UE103OS expansion module can be used:
•
in ac
cordance with EN ISO 13 849 up to PL e and category 4
•
in accordance with EN 62 061 to SILCL3
•
in accordance with IEC 61 508 up to SIL3
The actual performance level or SIL claim limit achieved depends on the external cir‐
cuit, the design of the wiring, the selection of the control switch and its placement on
the machine.
The UE10-3OS expansion module has been evaluated to UL 508.
The UE10-3OS expansion module is used for:
•
electro-sensitive protective equipment (ESPE) with monitored active output signal
switching device (OSSD): single-channel, dual-channel (in accordance with
IEC 61 4961)
•
safety devices with monitored semiconductor outputs, e.g. Flexi Classic and Flexi
Soft
The UE10-3OS has no restart interlock and no external device monitoring.
3.3 Intended use
The UE103OS expansion module must be used only as defined in section "F
ield of use
for the device", page 5 .
It must be used only by qualified safety personnel and only on the machine where it has
been installed and initialised by qualified safety personnel in accordance with the oper‐
ating instructions. If the device is used for any other purposes or modified in any way —
also during mounting and installation — any warranty claim against SICK AG shall
become void.
ON SAFETY 3
8022191/2017-11-24 | SICK O P E R A T I N G I N S T R U C T I O N S | UE10-3OS
5
Subject to change without notice