MLG-2 WebChecker | SICK
Process data structure / 프로세스 데이터 구조
IO-Link version V1.1
Process data length:
32 Byte In
1 Byte Out
Process Data In
Byte 0 1 2 3
Name Output Function 1 Output Function 2
Type UInt16 UInt16
Byte 4 5 6 7
Name Output Function 3 Output Function 4
Type UInt16 UInt16
Byte 8 9 10 11
Name Output Function 5 Output Function 6
Type UInt16 UInt16
Byte 12 13 14 15
Name Output Function 7 Output Function 8
Type UInt16 UInt16
Byte 16 17 18 19
Name Output Function 9 Output Function 10
Type UInt16 UInt16
Byte 20 21 22 23
Name Output Function 11 Output Function 12
Type UInt16 UInt16
Byte 24 25 26 27
Name Output Function 13 Output Function 14
Type UInt16 UInt16
Byte 28 29 30 31
Name Output Function 15 Output Function 16
Type UInt16 UInt16
Process Data Out
Byte 0
Name Process Data Out
Type UInt16
5 Troubleshooting
장애 해결
en
Meaning Sender LED Receiver LED Control panel LED
Supply voltage o or too low
All o All o All o
Hardware error
Red O Red O
Sensor teach-in or material
teach-in error
Red Ö 10 Hz +
Yellow o +
Green o
Alignment: Ö 10 Hz
RS-485 /
IO-Link: Ö 10 Hz
QoR-alarm
Yellow Ö 3 Hz +
Green O
Alignment
Ö 3 Hz
Sync error
Red O + Yellow
O
Short-circuit
Red O + Green
O
Meaning Measure
Supply voltage o or too low Check the supply voltage.
Hardware error Contact Service.
Meaning Measure
Sensor teach-in error Check that the front screens are clean.
Ensure that all light beams are unobstructed during
teach-in.
Check the alignment of the sender and receiver with
each other. Perform alignment again.
Perform sensor teach-in again.
Check “Blanking” in the SOPAS settings in the menu.
Material teach-in error No material is located between the sender and receiver.
The material is transparent.
Check “Blanking” and “Material teach-in” in the SOPAS
settings in the menu.
QoR-alarm Clean the sensor.
Check alignment.
Check the quality of the material
Sync error Check the electrical connection.
Check the electrical cables for breakage.
Short-circuit Contact Service. Replace the device.
ko
의미
송신기
LED
수신기 LED 조작 필드 LED
공급 전압이 꺼짐 또는 너
무 낮음
모두 o 모두 o 모두 o
하드웨어 결함
빨간색 O 빨간색 O
센서 티치인 또는
재료 티치인 오류
빨간색 Ö
10Hz + 노란색
o + 초록색 o
Alignment: Ö 10Hz
RS-485 /
IO-Link: Ö 10Hz
QoR 알람
노란색 Ö 3Hz
+ 초록색 O
Alignment
Ö 3Hz
동기화 오류
빨간색 O +
란색 O
단락
빨간색 O +
록색 O
의미 조치
공급 전압이 꺼짐 또는 너
무 낮음
공급 전압을 점검하십시오.
하드웨어 결함 서비스에 연락하십시오.
센서 티치인 오류 전면창이 깨끗한지 점검하십시오.
티치인 중에 모든 광선이 끊어지지 않도록 확
인하십시오.
송신기와 수신기가 서로 잘 정렬되었는지 점
검하십시오. 정렬을 다시 실행하십시오.
센서 티치인을 다시 실행하십시오.
SOPAS"블랭킹" 메뉴에서 설정을 점검하십
시오.
재료 티치인 오류 송신기와 수신기 사이에 물체가 없습니다.
재료가 투명합니다.
SOPAS"블랭킹" 메뉴 및 "재료 티치인" 메뉴
에서 설정을 점검하십시오.
QoR 알람 센서를 청소하십시오.
정렬 상태를 점검합니다.
재료 품질 점검
동기화 오류 전기 연결을 점검하십시오.
전기 케이블의 단선 여부를 점검하십시오.
단락
서비스에 연락하십시오. 장치를 교체하십시오.