6.10.1.1 Analog output menu
5.7.1 Activating the analog output
Table 21: Activating the analog output
TOP
A o u t o F F
Activates or deactivates the analog output.
select and adjust . The display reverts to the
Analog function top menu.
o F F
Not activated.
o u t
Activated.
5.7.2 Range configuration
Table 22: Range configuration
TOP
S P A n 4 A
Assignment of display values to analog output values
select and adjust . The display reverts to the
Detailed configuration menu.
4 A
Set 4mA.
2 0 A
Set 20mA.
Configuration
Applies to changing the display value, applies to digital
change and is for configuration. The display returns to Range
configuration
After setting the 4mA value, the display automatically
changes to the 20mA setting.
Maximal assignable display values are: Transmission, regres‐
sive reflection factor or reflection type: 0...4000 (proportion
of received light) Laser line in Lnth mode: 0...3000 (received
light = line width)
5.7.3 Defining invalid measured values
Table 23: Defining invalid measured values
TOP
c L P c L P
Select a measured value status when measurement is not
possible.
select and adjust . The display reverts to the
Defining invalid measured values menu.
c L P
Sets the output value to
approx. 24mA.
h o L d
Retains the last value
before the invalid status.
5.7.4 Moving average
OPERATING INSTRUCTIONS
8020148.1HRJ/2023-02-08 | SICK O P E R A T I N G I N S T R U C T I O N S | Evaluation unit WI130
57