EasyManua.ls Logo

SICK WLG16 Bluetooth

SICK WLG16 Bluetooth
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 3: Push / pull
Q
Push-pull
( 100 mA)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Q
Push-pull
( 100 mA)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Alarm
Alarm output: The sensor (WLG16) features a pre-failure notification output (“Alarm” in
connection diagram [Table 4]), which issues a notification if the sensor is only ready for
operation to a limited extent. The LED indicator flashes in this case. Possible causes:
Sensor or reflector is contaminated, sensor is out of alignment. In the good state: LOW
(0), if excessively contaminated HIGH (1).
Health
Health output: The sensor (WLG16) features a pre-failure notification output (“Health”
in connection diagram [Table 4]), which issues a notification if the sensor is only ready
for operation to a limited extent or the cable has been interrupted. Possible causes:
Sensor or reflector is contaminated, sensor is out of alignment, cable is damaged. In
the good state: HIGH (1), if excessively contaminated or in the event of cable interrup‐
tion LOW (0). The yellow LED indicator flashes in this case.
Table 4: Alarm / Health
Alarm ( 100 mA) Health (100 mA)
+ (L+)
Alarm
‒ (M)
+ (L+)
Alarm
‒ (M)
ELECTRICAL INSTALLATION 5
8022197 | SICK
Subject to change without notice
7