Do you have a question about the Siemens 7XT3300-0 A00 Series and is the answer not in the manual?
Brand | Siemens |
---|---|
Model | 7XT3300-0 A00 Series |
Category | Portable Generator |
Language | English |
Defines hazard levels DANGER and WARNING with associated safety instructions.
Details dangers associated with high voltage and required precautions for safe operation.
Details how the 7XT33 injects voltage and how fault resistance is determined.
Details the device's monitoring functions including start-up, overload, and output voltage checks.
Details control voltage ranges and pick-up thresholds for the blocking input.
Describes the function of jumper S1 in setting blocking input thresholds for different control voltages.
Lists manufacturers and part numbers for 4AT fusible cut-out inserts.
Lists manufacturers and part numbers for 5AT fusible cut-out inserts.
Details the rear view, side view, and mounting holes for the surface mounting version.
Details the side view, front view, and panel cut-out dimensions for flush mounting.
Explains proper use of screw-type terminals for connection and notes on delivery state.
Details requirements for bolt diameter, major diameter, and cross-section for cable lugs.
Outlines requirements for direct connection using solid or flexible wire, including strip length and torque.
Lists nominal and permissible DC and AC auxiliary voltage ranges.
Details the output voltage, power, and efficiency of the 20-Hz signal.
Explains adjustable voltage ranges and pick-up thresholds for the blocking input.
Details standards and test parameters for high-voltage and impulse voltage tests.
Lists standards and test parameters for high-frequency, electrostatic discharge, and irradiation tests.
Covers standards and parameters for surge voltages, power system frequency magnetic fields, and interference.
Details sinusoidal vibration and half-sine shock test parameters for the device during operation.
Outlines test parameters for vibration, shock, and continuous shock during transport.
Details permissible operating and storage temperatures, and admissible humidity levels.
Lists dimensions, mass, and IP20 degree of protection for the device housing.
Shows how to connect the 7XT33 to a DC voltage supply via a protective switch.
Depicts the connection for 100% stator earth fault protection using earthing or neutral transformer.
Provides order keys for surface-mounted and in-housing versions of the device.
Lists available accessories such as automatic circuit-breakers, fuses, and bandpass units with their order numbers.