9.2 Case 1: Personal Repair (green)
Step 1: Carry out step 1 – 4 to start SW-Update.
1
Select the mobile phone CPU type
3
4
Choose if customer data shall be erased.
If “Yes” activate the boxes in front of xfs
and mapping
Read out phone type/Variant.
>>Appears in the window
above.
2
Start SW-Update
Remarks:
- The decision about a Siemens authorised SW-Update depends only on the
Service Release-Table .
- The SW which is booted by GRT can be below the SW mentioned in the
Service Release Table, if this SW is not released for the Net-Operator
- If xfs and mapping are activated, GRT will erase in any case the customer
data even if the action is cancelled.
- If the user wants to download another variant then the automatically identified
one, he has simply to select another variant from the list. Afterwards he has to
start the SW-Update