Programming
4.5 ETHx_FTPC
CP 243-1
102 Operating Instructions, 03/2012, C79000-G8976-C244-02
Only one ETHx_FTPC subroutine can be active at any one time. Several FTP client requests
cannot be sent at the same time. As a result, it is advisable to link the "START" input with
both the return value "Done" of the ETHx_FTPC subroutine and the corresponding bit of the
return value "CH_Ready" from the ETHx_CTRL subroutine.
Call
ETHx_FTPC
START
EN
DONE
Done
ERR
E rro r
Op
OP
Abort
ABORT
Always_On
START_BIT
Figure 4-5 Calling the ETHx_FTPC subroutine
Input parameters
Name Type Meaning
START BOOL Input condition for triggering a
read/write/delete request
0: Do not trigger read/write/delete
request
1: Trigger read/write/delete request
Op BYTE FTP client request number from the
configuration that describes the
read/write/delete request to be
executed.
Value range: 0 .. 31
Abort BOOL Input condition for aborting of an FTP
client request
0: Do not abort FTP client request
1: Abort FTP client request
Input parameters (ETHx_FTPC)