Technical specifications
CP 5623/CP 5624
24 Operating Instructions, 09/2013, C79000-G8976-C281-03
Technical specifications of the CP 5623 / CP 5624
Vibration (EN 60068-2-6) 10 to 58 Hz
amplitude 0.075 mm
58 to 500 Hz,
2
2
Storage and transportation conditions Temperature
(EN 60068-2-1+2)
-20...+60 °C
Rel. humidity
≤ 95% at +25...+55 °C no condensation
Vibration (EN 60068-2-6) 8.51 to 500 Hz
acceleration 10 m/s
2
5 to 8.51 Hz,
2
Design, dimensions and weight
Weight
• For CP 5623
• For CP 5624
102 g
117 g
Dimensions (W x H x D)
• For CP 5623
• For CP 5624
21.6 x 126.3 x 180.5
21.6 x 126.3 x 180.5
Electromagnetic compatibility
Emission
• to EN 55022
• to FCC
Class B
Class B
Immunity On signal cables
• Surge to EN 610004-5
• Burst to EN 61000-4-3
±2 kV
±2 kV
to discharge of static electricity
• Contact discharge to IEC 61000-
4-2
to radiated radio frequencies
• to EN 61000-4-3
3 V/m with 80% amplitude modulation with
1 kHz, at 2 MHz – 2.7 GHz
10 V/m with 80% amplitude modulation with
1 kHz, at 80 MHz to 2 GHz
• to EN 61000-4-6
10 V/m 80% amplitude modulation with 1