Loading...
Fire Alarm Control Panel
Model FC901-U3/FC901-R3
Installation, Operation and Maintenance Manual
Siemens Industry Inc.

Table of Contents

Questions and Answers

  • G
    Glenda SparksSep 8, 2025
    What does 'CircuitTrouble' mean on my Siemens FC901-R3 Control Panel?
    • S
      Sharon JimenezSep 8, 2025
      If your Siemens Control Panel indicates circuit trouble, it means the battery charge circuit is in trouble.
  • M
    Michael FloresAug 23, 2025
    What does it mean if my Siemens FC901-R3 Control Panel says 'Short'?
    • M
      mullinsjamesAug 23, 2025
      If your Siemens Control Panel indicates a short, it means the device is experiencing a short trouble.
  • E
    Erin GallegosAug 25, 2025
    What does it mean if my Siemens FC901-R3 indicates a ground fault?
    • L
      lukerojasAug 25, 2025
      If your Siemens Control Panel shows a ground fault, it indicates the device is in a ground fault condition.
  • M
    Maria TuckerAug 26, 2025
    What does it mean when my Siemens Control Panel displays 'VoltageLow'?
    • B
      brittneybaileyAug 26, 2025
      If your Siemens Control Panel indicates a low voltage, it means the battery voltage is too low.
  • M
    millerericAug 27, 2025
    What does it mean when my Siemens Control Panel displays 'VoltageHigh'?
    • E
      Eugene MooreAug 27, 2025
      If your Siemens Control Panel displays a high voltage warning, it indicates that the battery voltage is too high.
  • A
    Amy GonzalezSep 22, 2025
    What does 'BatteryAbsent' mean on my Siemens FC901-R3 Control Panel?
    • J
      Jessica HessSep 22, 2025
      If your Siemens Control Panel indicates that the battery is absent, it means the battery is missing.
  • P
    Patricia KingSep 16, 2025
    What does 'AddressUnspecified' mean on my Siemens Control Panel?
    • T
      Taylor AllenSep 16, 2025
      If your Siemens Control Panel displays 'AddressUnspecified', it means that the SLC device has no address.
  • J
    jacobsanchezSep 18, 2025
    What does 'MessageLost' mean on my Siemens FC901-R3?
    • J
      Juan McbrideSep 18, 2025
      If your Siemens Control Panel indicates 'MessageLost', it means the DACT lost some messages because of limited memory space.
  • C
    colejoshuaSep 7, 2025
    What does 'FatalFault' mean on my Siemens FC901-R3?
    • S
      Sandra GonzalezSep 7, 2025
      If your Siemens Control Panel reports a fatal fault, it means the SLC device reported a fatal fault trouble.
  • B
    Beth RobinsonSep 4, 2025
    What does 'TypeMismatch' mean on my Siemens Control Panel?
    • B
      Brooke BaldwinSep 4, 2025
      If your Siemens Control Panel displays 'TypeMismatch', it means the SLC device type is not consistent with the config file.

Summary

INTRODUCTION

CONTROL PANEL LIMITATIONS

Outlines limitations of the control panel's functionality and connectivity.

PREFACE

FCC PART 68 WARNING

Details FCC compliance requirements and warnings related to telephone line connections.

DESCRIPTIONS

FC901 SYSTEM DESCRIPTION

Provides a comprehensive overview of the FC901 control panel's features and components.

OPTIONAL MODULES

Lists and describes optional modules that can be added to the FC901 system.

AUXILIARY MODULES

Details various auxiliary modules that enhance the functionality of the FC901 system.

SLC ADDRESSABLE DEVICES

Smoke Detector

Describes the function and features of addressable smoke detectors used with the panel.

Heat Detectors

Explains the use and programming of addressable heat detectors.

CONTROL PANEL OPERATION

Alarm Conditions

Explains how the panel indicates and handles alarm conditions.

POSITIVE Alarm Sequence (PAS)

Details the Positive Alarm Sequence feature for delayed output activation.

PRE-SIGNAL ALARMS

Describes the Pre-Signal feature for delayed alarm notification.

Trouble Conditions

Explains how the panel indicates and handles trouble conditions.

Supervisory Conditions

Details how the panel indicates and handles supervisory conditions.

FC901 OPERATING INSTRUCTIONS

Alarm Operation

Details the sequence of events and actions during an alarm condition.

Trouble Operation

Explains how the panel indicates and responds to trouble conditions.

Fuse Replacement and Battery Maintenance

Instructions for fuse replacement and battery maintenance procedures.

CONTROL PANEL INSTALLATION

Enclosure Mounting

Instructions for securely mounting the control panel enclosure.

Battery Installation

Procedures for installing the system batteries.

CAUTIONS

SYSTEM WIRING

Wiring Separation

Critical information on separating power-limited and non-power-limited wiring.

Power Supply and Battery Wiring

Details on wiring the power supply and battery connections.

NAC Wiring

Wiring diagrams and specifications for Notification Appliance Circuits.

Serial Interface Circuit (UFP) Wiring

Wiring specifications for the Serial Interface Circuit.

SLC Addressable Device Circuit Wiring

Specifications for the SLC addressable device circuit.

SLC NFPA Style 4 Wiring

Wiring diagram and operation for NFPA Style 4 SLC circuits.

SLC NFPA Style 6 Wiring

Wiring diagram and operation for NFPA Style 6 SLC circuits.

PROGRAMMING THE CONTROL PANEL

MAINTENANCE

QUICK TEST

APPENDIX-C: TROUBLESHOOTING

A. General

Definitions of general event history entries and their indications.

B. System Events

Definitions of system events and their corresponding notes.

APPENDIX-D: ALARM VERIFICATION

APPENDIX-E: APPLICATION SPECIFIC DETECTION

APPENDIX-F: TESTING;MAINTENANCE

BATTERY MAINTENANCE

Tests and replacement schedule for system batteries.

APPENDIX-G: LCD, CONTROLS AND INDICATORS

LEDs, Buzzer and Dedicated Push Buttons

Explanation of the function of panel LEDs, buzzer, and buttons.

APPENDIX-I: PAS; PRE-SIGNAL

PAS

Details the Positive Alarm Sequence feature and its operation.

Pre-Signal

Explains the Pre-Signal feature for delayed alarm notification.