DANGER
*
Hazardous
Voltage
.
Will
cause
death
or
severe
injury
.
Turn
power
off
supplying
switchboard
or
panel
before
installing
.
j
r
A
Safety
Instructions
Mounting
Block
(
Figure
3
)
A
.
Align
mounting
block
(
2
)
with
cutouts
in
switchboard
mounting
plate
(
or
customer
'
s
mounting
means
as
previ
-
ously
prepared
in
Step
B
above
)
and
secure
in
place
with
5
/
16
"
lockwashers
(
3
)
and
5
/
16
"
bolts
(
4
)
furnished
.
General
A
complete
plug
-
in
installation
requires
one
line
end
adapter
assembly
(
consisting
of
a
mounting
block
,
tulip
connectors
and
associated
hardware
)
,
one
load
end
adapter
assembly
and
one
switchboard
mounting
plate
.
The
switchboard
mounting
plate
is
optional
and
can
be
replaced
by
other
mounting
means
to
suit
customer
'
s
requirements
.
Breaker
Preparation
(
Figure
4
)
A
.
Remove
pressure
wire
connectors
from
breaker
if
present
.
Place
tulip
clip
assembly
(
5
)
on
back
of
breaker
in
recess
provided
in
base
molding
.
Secure
in
place
with
1
/
4
"
belleville
washers
(
6
)
and
1
/
4
"
-
20
x
1
hex
head
bolts
(
7
)
furnished
.
Recommended
tightening
torque
for
these
bolts
is
5
-
6
ft
.
-
ibs
.
to
assure
a
good
electrical
connection
.
Repeat
this
procedure
for
the
remaining
tulip
clip
assemblies
.
B
.
Insert
line
end
shields
(
8
)
into
slots
provided
at
line
and
load
end
of
breaker
.
No
lower
end
shields
are
required
.
C
.
Affix
accessory
warning
labels
(
9
)
to
top
of
breaker
as
indicated
in
Figure
5
.
Application
Information
f
Switch
-
board
Mtg
.
Plate
Cat
.
No
.
Line
End
Adapter
Cat
.
No
.
Load
End
Adapter
Cat
.
No
.
Breaker
Type
No
.
of
Poles
JXD
2
(
-
A
}
,
JXD
6
,
(
-
A
)
,
HHJD
6
,
HHJXD
6
,
JD
6
(
-
A
)
,
HJD
6
(
-
A
)
,
HJXD
6
(
-
A
)
PC
5777
PC
5778
2
PC
5777
PC
5778
PL
5796
PL
5796
3
LXD
6
(
-
A
}
(
LD
6
(
-
A
)
,
HLD
6
(
-
A
)
,
HLXD
6
(
-
A
)
,
HHLXD
6
,
HHLD
6
PC
5660
PC
5661
PL
5796
PL
5796
2
PC
5660
PC
5661
3
Final
Assembly
(
Figure
6
)
A
.
Make
bus
connections
to
flat
bar
connectors
at
rear
of
mounting
blocks
with
customer
supplied
5
/
16
"
hardware
(
see
Figure
6
for
hole
pattern
)
.
Caution
:
Make
certain
that
breaker
operating
handle
is
in
the
OFF
position
before
proceeding
with
the
next
step
.
B
.
Align
breaker
with
mounting
blocks
and
force
female
tulip
clips
over
male
studs
in
mounting
blocks
until
breaker
base
bottoms
against
mounting
block
.
Secure
breaker
in
place
with
1
/
4
-
20
x
3
"
mounting
screws
(
10
)
,
lockwashers
(
11
)
and
flatwashers
(
12
)
furnished
.
C
.
If
installation
requires
use
of
front
panel
trim
,
provide
cutout
for
breaker
escutcheon
(
Figure
7
)
.
PC
5777
PC
5778
PL
5797
PL
5797
2
PC
5777
PC
5778
CJD
6
,
CJD
6
-
ETI
3
PC
5660
PC
5661
PC
5660
PC
5661
PL
5797
PL
5797
2
CLD
6
,
CLD
6
-
ETI
3
Mounting
Preparation
(
Figures
1
and
2
)
A
.
If
the
switchboard
mounting
plate
(
PL
5796
,
PL
5297
)
(
1
)
is
to
be
used
,
provide
drilling
as
shown
in
Figure
1
.
B
.
If
other
mounting
means
are
to
be
used
,
provide
the
cutouts
and
drilling
required
to
mount
the
adapter
blocks
as
shown
in
Figure
2
.
Switchboard
Mounting
Plate
,
if
used
(
Figure
3
)
A
.
Place
switchboard
mounting
plate
(
1
)
in
position
at
location
previously
prepared
in
Step
A
above
.
Secure
in
place
with
5
/
16
"
.
Lockwashers
(
3
)
and
5
/
16
"
bolts
(
4
)
furnished
.
%
14
CLD6(-A), CLD6-ETI
CJD6(-A), CJD6-ETI