EasyManua.ls Logo

Siemens JXD2 - Page 42

Siemens JXD2
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Max
-
Flex
Flange
-
Mount
Handle
Operator
Types
1
,
3
,
3
R
,
4
,
4
X
,
12
F
.
Place
the
four
spacers
(
21
)
into
the
breaker
mounting
holes
.
G
.
Fasten
circuit
breaker
operating
mechanism
(
22
)
onto
cir
-
cuit
breaker
with
four
lockwashers
(
23
)
and
four
1
/
4
-
20
x
1
-
3
/
4
"
screws
(
24
)
.
B
.
Trip
the
circuit
breaker
by
pressing
the
PUSH
TO
TRIP
but
-
ton
on
the
front
of
the
circuit
breaker
.
Check
that
the
circuit
breaker
resets
by
moving
the
operat
-
ing
handle
(
2
)
from
ON
to
OFF
and
back
to
ON
.
If
the
breaker
resets
,
tighten
the
spring
adjuster
(
31
)
one
addi
-
tional
turn
.
Attach
the
lockwasher
and
#
10
-
32
locknut
(
32
)
to
the
end
of
the
cable
rod
,
and
tighten
the
locknut
.
If
the
circuit
breaker
does
not
reset
after
Step
B
,
tighten
the
spring
adjuster
(
35
)
one
turn
and
repeat
Step
B
.
Continue
this
procedure
until
the
breaker
does
reset
,
then
tighten
the
adjuster
spring
one
additional
turn
.
Secure
with
the
lockwasher
and
locknut
(
36
)
.
C
.
Securing
Operating
Cable
to
Frame
Assembly
A
.
To
attach
the
operating
cable
(
16
)
to
the
frame
assembly
(
4
)
,
move
the
operating
handle
(
2
)
to
the
ON
position
and
attach
the
cable
swivel
(
25
)
to
the
outer
hole
of
the
bell
-
crank
(
6
)
.
Secure
the
connection
with
an
E
Ring
(
Figure
7
)
.
D
.
Tighten
Detent
Screws
B
.
Secure
the
cable
(
16
)
to
the
frame
assembly
(
4
)
by
placing
it
between
the
cable
retainer
clip
(
26
)
and
the
shim
(
27
)
,
secure
with
two
#
10
-
32
x
3
/
8
"
screws
and
lockwashers
.
NOTE
:
Detent
(
28
)
in
cable
retainer
must
align
with
the
groove
(
29
)
in
the
cable
'
s
metal
fitting
(
Figure
7
)
.
Securing
Operating
Cable
to
Circuit
Breaker
NOTE
:
Before
attaching
the
cable
to
the
circuit
breaker
,
installers
must
confirm
that
the
power
from
the
supply
source
has
been
de
-
energized
.
A
.
Move
the
circuit
breaker
handle
to
the
ON
position
.
B
.
Remove
the
soft
plastic
cap
from
the
end
of
the
threaded
cable
rod
(
30
)
and
slide
the
rod
through
the
hole
in
the
sliding
plate
tab
(
31
)
of
the
circuit
breaker
operating
mech
-
anism
(
22
)
(
Figure
8
)
.
C
.
Move
the
flange
mount
operating
handle
(
2
)
to
its
maxi
-
mum
ON
position
and
hold
it
in
place
.
D
.
Place
the
cable
mounting
threads
(
30
)
into
the
slot
on
the
fixed
plate
tab
(
32
)
so
that
the
two
mounting
nuts
(
33
)
are
on
both
sides
of
the
tab
.
Adjust
the
two
mounting
nuts
so
that
the
#
10
-
32
nut
on
the
cable
rod
just
touches
the
slid
-
ing
plate
tab
(
31
)
.
Tighten
the
mounting
nuts
(
33
)
to
secure
the
cable
(
Figure
8
)
.
E
.
Continue
holding
the
operating
handle
in
the
ON
position
and
place
the
spring
(
34
)
over
the
end
of
the
rod
.
Screw
on
the
spring
adjuster
(
35
)
and
tighten
until
it
begins
to
compress
the
spring
.
Do
not
overtighten
.
Figure
8
Fixed
Plate
Adjustment
Making
Cable
Adjustments
A
.
Check
that
circuit
breaker
turns
OFF
and
ON
by
moving
the
operating
handle
(
2
)
up
for
ON
and
down
for
OFF
.
If
the
breaker
does
not
switch
ON
,
loosen
the
cable
mount
-
ing
nuts
(
29
)
at
the
fixed
plate
tab
(
28
)
,
hold
the
operating
handle
in
the
maximum
ON
position
,
and
move
the
cable
(
16
)
toward
the
top
of
the
breaker
.
Retighten
the
mounting
nuts
(
29
)
to
secure
.
m
40
Side
View
of
Max
-
Flex
Handle
Operator
Spring
Adjustment
Courtesy of NationalSwitchgear.com

Related product manuals