133
LOGO! Manual
A5E00067781 01
You cannot change the unit of the delay time for the param-
eter T in parameterization mode. This is only possible in
programming mode.
Current value of a time T
If you view a time T in parameterization mode, it looks like
this:
B01:T
T
a
= 00:00m
T = 12:00m
Time T set
Current time T
a
You can change the set time T (see ”Changing a parame-
ter).
Current value of the time switch
If you view a cam of a time switch in parameterization
mode, it looks like this, for example:
The time switch is off
(state ’0’ at the output)
The time switch is on
(state ’1’ at the output)
B02:No1
Off=10:00
Day = Su
The circuit state of the time switch
is displayed:
On =09:00
1
1
0
LOGO! displays the circuit state of the time switch rather
than the circuit state of a cam. The circuit state of the time
switch depends on all three cams (No1, No 2 and No 3).