B-5
Manual OP5, OP15
( ) J31069-D0840-U001-A2-7618
ActionCauseMessage
$ 303 PLC did not invert life flag. Data
have not been requested or are no
longer valid
Check PLC status
$ 304 Invalid job number or job parame-
ters
Modify job on PLC
$ 305 Data block number x missing Create the data block that is missing
$ 306 Temporary driver error
$ 307 Counter x not present on PLC Modify configuration
(variable)
$ 308 Timer x not present on PLC Modify configuration
(variable)
$ 309 Input x not present on PLC Modify configuration
(variable)
$ 310 Output x not present on PLC Modify configuration
(variable)
$ 311 Flag x not present on PLC Modify configuration
(variable)
$ 312 Print job rejected because similar
job now being executed
Wait until previous job terminated; initiate
again
$ 313 Print job will be processed later be-
cause printer now busy
$ 315 Information text has not been con-
figured for highlighted object (e.g.
message, variable)
$ 316
$ 317
Current password level too low for
required operator input
Log in at higher password level
$ 318 Login attempted with invalid pass-
word
$ 319 You entered and tried to edit an ex-
isting password
$ 320
$ 321
Enter password first, and then specify level
$ 322 Password must contain at least 3 characters
$ 323 In a buffer mask, you pressed
(message text), though an
entry does not exist for the current
message.
$ 324 The screen number or entry number
in your input does not exist