B-9
Manual OP5, OP15
( ) J31069-D0840-U001-A2-7618
ActionCauseMessage
$ 620 Wrong parameter transferred by
ProTool/Lite (function keyboard)
Repeat download of configuration
$ 621 Wrong parameter transferred by
ProTool/Lite (message type)
Set required value by means of standard
screen or PLC
$ 622 Configured recipe does not fit in the
recipe mailbox (greater than 256
data words).
Configure recipe shorter or set up subsequent
recipe mailbox on line device
$ 623 See Internal Errors
$ 624 No recipe entries exist. Configure recipe again.
$ 625 Invalid recipe number in the PLC
job
$ 626 No variables configured in the
recipe
Configure recipe again.
$ 628 Recipe too long for the mailboxes Configure recipe shorter.
$ 629 LED image area too small Enlarge LED image area according to config-
ured bit offsets
$ 630 Keyboard image area too small Enlarge image area according to configured
bit offsets
$ 631 (Message with one variable)
1, 2 Initiated alarm message
not configured
5, 6 Initiated event message
not configured
8 to 20 Internal errors
25 Invalid field type
Add to configuration and repeat download
$ 632 (Message with one variable)
1, 4 Information text not
available
2 Information text identi-
fier not available for
messages
12 Process screen does not
contain entries
3, 6, 7, Internal errors
8, 11, 13
Add to configuration and repeat download
$ 634 (Message with one variable)
18 Screen title or recipe title
not configured
0 to 8, Internal errors
34
Add to configuration and repeat download