C-2
Manual OP5, OP15
( ) J31069-D0840-U001-A2-7618
OP5 OP15
A1 A2 A1 A2 A1-VF A2-VF C1 C2
Keyboard
Type Membrane keyboard
Number of system keys 24
Number of LEDs 4 20
Number of function
keys
6 16
Softkeys 4 8
Supply voltage
Rated voltage 24 VDC
Permissible range 18 to 30 VDC
Maximum permissible
transients
35 V (500 ms)
Time between tran-
sients
min. 50 sec.
Power input
Typically
Maximum
180 mA
250 mA
200 mA
300 mA
Fuse internal
Backup battery
1
Type Lithium cell
Voltage 3.6 V
Capacity 1.5 Ah
1 Subject to change
Authorization input
Inhibited U < 3.6 V or open input
Enabled 15 V < U < 30 V