EasyManuals Logo

Siemens Open Processor User Manual

Siemens Open Processor
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
Open Processor with Trane Driver Owner's Manual
5-8 Siemens Building Technologies, Inc.,
Landis Division
T
TT
Ta
aa
ab
bb
bl
ll
le
e e
e 5
55
5-
--
-5
55
5.
. .
. S
SS
St
tt
ta
aa
an
nn
nd
dd
da
aa
ar
rr
rd
d d
d BC
BCBC
BCU
U U
U I
II
In
nn
np
pp
pu
uu
ut
tt
t/
//
/O
OO
Ou
uu
ut
tt
tp
pp
pu
uu
ut
t t
t O
OO
Ob
bb
bj
jj
je
ee
ec
cc
ct
tt
ts
ss
s.
..
.
BCU #1
Job Name: M
MM
My
y y
y E
EE
Exa
xaxa
xam
mm
mp
pp
pl
ll
le
ee
e Device Address: 1
11
1 Network Address: 1
11
1
O
OO
Ob
bb
bj
jj
je
ee
ec
cc
ct
tt
t
T
TT
Ty
yy
yp
pp
pe
ee
e
S
SS
Se
ee
eq
qq
quen
uenuen
uent
tt
ti
ii
ia
aa
al
ll
l
N
NN
Nu
uu
um
mm
mb
bb
be
ee
er
rr
r
G
GG
Gene
eneene
ener
rr
ri
ii
ic
cc
c
D
DD
Da
aa
at
tt
ta
a a
a N
NN
Na
aa
am
mm
me
ee
e
O
OO
Ob
bb
bj
jj
je
ee
ec
cc
ct
t t
t I
II
ID
DD
D S
SS
Si
ii
ie
ee
em
mm
men
enen
ens
ss
s
F
FF
FL
LL
LN
NN
N
S
SS
Si
ii
ie
ee
em
mm
men
enen
ens
ss
s
D
DD
DR
RR
RO
OO
OP
PP
P
S
SS
Si
ii
ie
ee
em
mm
men
enen
ens
ss
s
P
PP
PO
OO
OI
II
IN
NN
NT
TT
T
AIP 1 UCP1 CTV Leaving Chilled Water Temperature 00-00-00-01 1 0 1
AIP 2 UCP1 CTV Return Chilled Water Temperature 00-00-00-02 1 0 2
AIP 3
UCP1 CTV Leaving Condenser Water
Temperature 00-00-00-03 1 0 3
AIP 4
UCP1 CTV Return Condenser Water
Temperature 00-00-00-04 1 0 4
AIP 5 UCP1 CTV Percent RLA 00-00-00-05 1 0 5
AIP 6 UCP1 CTV Condenser Refrigerant Pressure 00-00-00-06 1 0 6
AIP 7
UCP1 CTV Compressor Discharge Refrigerant
Temperature 00-00-00-07 1 0 7
AIP 8 UCP1 CTV Evaporator Refrigerant Temperature 00-00-00-08 1 0 8
AIP 9 UCP1 CTV Condenser Refrigerant Temperature 00-00-00-09 1 0 9
AIP 10 UCP1 CTV Oil Temperature 00-00-00-0A 1 0 10
AIP 11
UCP2 ABS Leaving Chilled Water Temperature
00-00-00-0B 1 0 11
AIP 12 UCP2 ABS Return Chilled Water Temperature 00-00-00-0C 1 0 12
AIP 13
UCP2 ABS Leaving Condenser Water
Temperature 00-00-00-0D 1 0 13
AIP 14
UCP2 ABS Return Condenser Water
Temperature 00-00-00-0E 1 0 14
AIP 15 UCP2 ABS Evaporator Refrigerant Pressure 00-00-00-0F 1 0 15
AIP 16 UCP2 ABS Condenser Refrigerant Pressure 00-00-00-10 1 0 16
AIP 17 UCP2 ABS Evaporator Refrigerant Temperature 00-00-00-11 1 0 17
AIP 18 UCP2 ABS Condenser Refrigerant Temperature 00-00-00-12 1 0 18
AIP 19
UCP2 ABS Leaving Steam Condensate
Temperature 00-00-00-13 1 0 19
BIP 1 UCP1 CTV Chiller Status 03-00-00-01 1 3 1
BIP 2 UCP1 CTV Condenser Water Flow 03-00-00-02 1 3 2
BIP 3 UCP1 CTV Chilled Water Flow 03-00-00-03 1 3 3
BIP 4 UCP1 CTV Manual Reset Alarm 03-00-00-04 1 3 4
BIP 5 UCP1 CTV Auto Reset Alarm 03-00-00-05 1 3 5
BIP 6 UCP1 CTV UCP Communications 03-00-00-06 1 3 6
BIP 7 UCP2 ABS Chiller Status 03-00-00-07 1 3 7
BIP 8 UCP2 ABS Absorber/Condenser Water Flow 03-00-00-08 1 3 8
BIP 9 UCP2 ABS Chilled Water Flow 03-00-00-09 1 3 9
BIP 10 UCP2 ABS Manual Reset Alarm 03-00-00-0A 1 3 10
BIP 11 UCP2 ABS Auto Reset Alarm 03-00-00-0B 1 3 11
BIP 12 UCP2 ABS UCP Communications 03-00-00-0C 1 3 12
BOP 1 UCP1 CTV Chiller Enable/Disable 04-00-00-01 1 4 1
BOP 2 UCP2 ABS Chiller Enable/Disable 04-00-00-02 1 4 2
AOP 1 UCP1 CTV Chilled Water Set Point 01-00-00-01 1 1 1
AOP 2 UCP1 CTV Demand Limit Set Point 01-00-00-02 1 1 2
AOP 3 UCP2 ABS Chilled Water Set Point 01-00-00-03 1 1 3