Room Unit for Boiler Control
With OpenTherm Interface
User manual
QAA73.210
Edition 1.1
Device series A
CE1U2283en
2015-09-16 Building Technologies
Question and Answer IconNeed help?

Do you have a question about the Siemens QAA73.210 and is the answer not in the manual?

Siemens QAA73.210 Specifications

General IconGeneral
TypeControl Unit
ModelQAA73.210
ManufacturerSiemens
Power Supply24 V AC / DC
Frequency50/60 Hz
Mounting TypeDIN Rail
Degree of ProtectionIP20
Input Voltage24 V
Humidity Range10% to 95% (non-condensing)

Summary

1 Overview

1.1 Features

Lists the key features of the room unit, covering operating modes, functions, and additional capabilities.

2 Mounting and Installation

1.2 Product Liability

Details the conditions for product usage and compliance with regulations.

1.3 Disposal

Explains the proper disposal procedures for electronic waste according to directives.

2.1 Engineering

Discusses the considerations for selecting the mounting location and height for optimal room temperature sensing.

3 Commissioning

3.1 Operational Faults

Lists common operational issues and their potential causes and checks for the room unit and boiler control.

4 Handling

4.1 Operation

Explains the basic operation of the room unit, including operating elements, buttons, and display icons.

Selection of Space Heating Mode

Details the different space heating modes (Automatic, Continuous, Protection, Cooling) and their characteristics.

DHW Heating Mode Selection

Describes how to switch Domestic Hot Water (DHW) heating on/off and set temporary setpoints.

Temperature Setpoint Adjustment

Explains how to adjust comfort and reduced room/DHW temperature setpoints using the unit's buttons.

Presence Button Function

Details the function of the presence button for reducing room temperature and saving energy during unoccupied periods.

Displaying Information

Explains how to view various data points and system parameters using the info button.

Fault Indication and Codes

Details how the unit indicates errors and lists common error codes with their descriptions.

Boiler Lockout and Reset

Explains how boiler lockout is displayed and the procedure to reset the BMU.

Chimney Sweep and Controller Stop

Describes the chimney sweep function and controller stop status, and how modulation level can be set.

4.2 Programming Room Unit Parameters

4.2.1 User Levels

Describes the different user levels (End user, Heating engineer, OEM) and how to access them for settings.

4.2.2 Overview of Settings

Provides a comprehensive table of all configurable settings for heating, cooling, and DHW, including their ranges and default values.

5 Description of Room Unit Settings

5.1 Time and Day (TIME)

Emphasizes the importance of correctly setting the time and day for program operation.

5.2 Time Switch Program (TSPHC, TSPCC)

Covers defining day selection and specific switching times for heating and DHW programs.

5.3 Heating Circuit (HEAT)

Details settings for comfort, reduced, and frost protection temperatures, flow limitations, and heating curve slope.

Summer/Winter Changeover Temperature (SUWI)

Describes the criterion for automatic switching between summer and winter heating modes based on temperature.

24-Hour Heating Limit (ECO24)

Explains the function of switching heating on/off based on outside temperature for short-term variations.

Gain Factor of Room Influence (KORR)

Defines how room temperature deviations influence the controlled system and how to adjust this factor.

Quick Setback (QSETB)

Explains the function of quick setback, deactivating the heating circuit pump temporarily.

Room Temperature Maximum Limitation (SDR)

Describes the function used for room temperature limitation to prevent overheating and its effect on switching differential.

5.4 Cooling Circuit (COOL)

5.5 Domestic Hot Water (DHW)

DHW Nominal and Reduced Setpoints

Covers nominal and reduced DHW setpoints, maximum/minimum limits for hot water temperature.

Legionella Function (L FCT)

Details the function that periodically raises DHW temperature to prevent legionella bacteria growth.

5.6 Configuration (CONF)

DHW and Cooling Enable Settings

Explains settings to enable/disable DHW time switch programs and the cooling function.

6 Functions

6.1 Types of Compensation

Outlines weather compensation, room influence, and fix flow temperature setpoint methods for temperature control.

6.1.1 Weather Compensation

Explains how building heat losses are compensated by adequate flow temperature based on outside conditions.

6.1.2 Weather Compensation with Room Influence

Describes enhanced comfort through feedback from room influence, adjusting flow temperature based on room conditions.

6.1.3 Room Compensation

Details the PID control algorithm for room compensation, using actual room temperature and its gradient.

6.1.4 Fix Flow Temperature Setpoint

Explains how to manually set a fixed flow temperature setpoint, requiring specific prerequisites.

7 Dimensions

Unit Dimensions and Panel Cutout

Provides physical dimensions of the unit and specifications for panel cutout for installation.

8 Technical Data

Technical Specifications Overview

Lists key technical data including power supply, measurement ranges, environmental conditions, standards, and software class.