Siemens RDF301, RDF301.50..., RDF600KN, RDF600KN/S Basic Documentation CE1P3171en
Building Technologies 2017-12-07
Operating modes: Comfort, Economy (Energy Saving) and Protection
ON/OFF or 3-position control outputs (relay)
Output for 3-speed or 1-speed fan
Automatic or manual heating / cooling changeover
Backlit display
AC 230 V operating voltage
RDF600KN… for round CEE conduit box, with min 60 mm diameter,
min 40 mm depth or recessed square CEE conduit box
with 60.3 mm fixed centers
RDF301… for recessed square CEE conduit box
with 60.3 mm fixed centers
Room temperature control via built-in temperature sensor or external room
temperature / return air temperature sensor.
Changeover between heating and cooling mode (automatic via local sensor or
bus, or manually).
Selection of applications via DIP switches or commissioning tool.
Select operating mode via operating mode button on the thermostat.
Temporary Comfort mode extension.
1- or 3-speed fan control (automatically or manually).
Display of current room temperature or setpoint in °C and/or °F.
Minimum and maximum limitation of room temperature setpoint.
Button lock (automatically or manually).
2 multifunctional inputs, freely selectable for:
Sensor for automatic heating / cooling changeover
External room temperature or return air temperature sensor
Dew point sensor
Electric heater enable
Fault input
Monitor input for temperature sensor or switch state
RDF301…
Operating mode switchover contact … (keycard, window contact, etc.)
RDF600KN…:
Window contact
Presence detector (Standard presence mode and Hotel presence )
See pages 15 & 18.
Advanced fan control function, e.g. fan kick, fan start, selectable fan operation
(enable, disable or depending on heating or cooling mode).
"Purge" function together with 2-port valve in a 2-pipe changeover system.
Reminder to clean fan filters (adjust with P62).
Floor heating temperature limitation.
Reload factory settings for commissioning and control parameters.
Features
Type of mounting /
suitable conduit boxes
Functions

Table of Contents

Other manuals for Siemens RDF301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RDF301 and is the answer not in the manual?

Siemens RDF301 Specifications

General IconGeneral
BrandSiemens
ModelRDF301
CategoryThermostat
LanguageEnglish

Related product manuals