Siemens Building Technologies Basic Documentation RVA63.242, RVA53.242 CE1P2373E
Landis & Staefa Division Summary 26.03.2001
Frost protection for the house or building, the plant, d.h.w., the heating circuit, and
the boiler
Protection for the pump and the mixing valve through periodic control (pump and
valve kick)
Adjustable minimum and maximum limitation of flow temperature
Protection against overtemperatures in the pump heating circuit
Two 7-day heating programs
7-day heating program no. 1 for heating circuit 1
7-day heating program no. 2, selectable for heating circuit 2, or the d.h.w.
circulating pump
Separate 7-day heating program for d.h.w. heating
Temperature adjustment with the setpoint knob
Automatic button for efficient operation throughout the year
Chimney sweep function at the touch of a button
Manual operation at the touch of a button
Straightforward selection of operating mode via buttons
Change of operating mode with H-contact
Output and input tests to assist commissioning and a functional test
Service connection facility for local parameter settings and data logging
D.h.w. heating with a charging pump or diverting valve
D.h.w. heating with one or 2 sensors
Reduced setpoint of d.h.w. temperature
Selectable d.h.w. program
Integrated legionella function
Selectable priority for d.h.w. heating
Adjustable boost of the d.h.w. charging temperature
Automatic d.h.w. push
D.h.w. demand with a sensor or thermostat
Protection against discharging
D.h.w. heating: with solar heat
D.h.w. circulating pump
Electrical immersion heater
Communicating via Local Process Bus (LPB)
1)
Communicating via point-to-point interface (PPS)
Integrity of system architecture with all RVA... controllers
1)
Can be extended to include up to 40 heating circuits (with central bus power
supply)
1)
Optional remote supervision
Fault status signals and indications (locally, LPB and PPS)
1)
Controllers of other manufacture can deliver their heat demand signal via potential-
free H-contact
Controllers of other manufacture can deliver their heat demand via DC 0…10 signal
Analysis with service tool
1)
Logging the number of burner hours run of stages 1 and 2
Logging the number of burner starts of stages 1 and 2
Logging the flue gas temperature
Display of plant diagram no.
1)
Not with RVA53.242
Operation
D.h.w.
Use in extensive
systems
Logging