EasyManuals Logo

Siemens SCALANCE S615 User Manual

Siemens SCALANCE S615
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
Description of the device
3.9 PLUG
SCALANCE S615
30 Operating Instructions, 10/2022, C79000-G8976-C389-07
PLUGs. The CLP is also referred to as PLUG in the description. The PLUG is available in the
following variants:
PLUG Configuration
PLUG License
Position
The PLUG slot is located on the back of the device, see the Device views (Page 22) section in
the Operating Instructions of the device.
Function
Devices with a PLUG slot support the following operating modes:
Without PLUG
The device saves the configuration data in the internal memory. This mode is active when
no PLUG is inserted.
With PLUG
In the startup phase:
If an empty PLUG (as supplied) is inserted in the device, the device automatically backs
up the configuration data on the PLUG during startup. After that, it behaves like a PLUG
with data.
When a PLUG with data is plugged into a device, the device automatically adopts the
configuration of the PLUG during the startup phase. The prerequisite for this is that the
configuration data was written by a compatible device type.
One exception to this can be the IP configuration if it is set using DHCP and the DHCP
server has not been reconfigured accordingly. Reconfiguration is necessary if you use
functions based on MAC addresses.

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals