Connection
5.6 Grounding
SCALANCE W774-1 /W734-1
Operating Instructions, 01/2017, C79000-G8976-C325-08
49
5.6
Grounding
Grounding with wall mounting
The device is grounded by the securing screw in the unpainted hole (diameter 4.5 mm) see
position
of the Device description (Page 11).
If the device is mounted on a non-conductive base, a grounding cable must be fitted. The
grounding cable is not supplied with the device. Connect the paint-free surface of the device
to the nearest grounding point using the grounding cable.
Grounding when installing on a DIN rail / S7 standard rail
The device is grounded via the rear of the device.