Upkeep and maintenance
6.2 Restoring the factory settings
SCALANCE W774-1 /W734-1
52 Operating Instructions, 01/2017, C79000-G8976-C325-08
When pressing the button, make sure you adhere to the instructions in the section "Reset
button".
To reset the device to the factory defaults during the startup phase, follow the steps below:
1. Turn off the power to the device.
2. Loosen the screws of the cover.
3. Remove the cover.
4. Press the reset button and reconnect the device to the power supply while holding down
the button.
5. Hold down the button until the red error LED "F" stops flashing after approximately 10
seconds and is permanently lit.
6. Release the button and wait until the fault LED "F" goes off.
The device starts automatically with the factory settings.
7. Close the cover (tightening torque 0.8 Nm), to ensure that the device is closed and water
and dust proof.
You will find detailed information on resetting the device parameters using the WBM and CLI
in the configuration manuals:
● Web Based Management, section "Restart"
● Command Line Interface, section "Reset and Defaults"