Loading...
Assembling
4.7 Installation on a standard rail
SCALANCE X-300
40 Compact Operating Instructions, 05/2016, A5E00982643-14
4.7
Installation on a standard rail
Installation on a SIMATIC S7-300 standard rail
1. Place the upper guide at the top of the IE Switch X-300 housing in the S7 standard rail.
2. Screw the IE Switch X-300 to the underside of the standard rail.
3. Fit the connectors for the power supply.
4. Fit the connectors for the signaling contact.
5. Insert the terminal blocks into the sockets on the IE Switch X-300.
Image 4-3 IE Switch X-300 installation on a SIMATIC S7-300 standard rail
Uninstalling
To remove an IE Switch X-300 from the SIMATIC S7-300 standard rail:
1. First disconnect all connected cables.
2. Loosen the screws on the underside of the S7 standard rail and lift the IE Switch X-300
away from the rail.