Connecting
5.6 Power supply
SCALANCE X-300
48 Compact Operating Instructions, 05/2016, A5E00982643-14
5.6
Power supply
5.6.1
24 VDC - product group X-300
Table 5- 2 24 to 48 VDC safety extra-low voltage overview
Device
Device version
(power supply)
24 V safety extra-low voltage
(SELV)
can be connected redundantly
X304-2FE
1 x 24 VDC
X306-1LD FE
1 x 24 VDC
X307-3
1 x 24 VDC
X307-3LD
1 x 24 VDC
X308-2
1 x 24 VDC
X308-2LD
1 x 24 VDC
X308-2LH
1 x 24 VDC
X308-2LH+
1 x 24 VDC
X310
1 x 24 VDC
X310FE
1 x 24 VDC
X320-1 FE
1 x 24 VDC
X320-3LD FE
1 x 24 VDC
5.6.2
Power supply
WARNING
Operation only with safety extra-low voltage
The IE Switch X-300 is designed for operation with safety extra-low voltage (SELV).
This means that only safety extra-low voltages (SELV) complying with
IEC950/EN60950/ VDE0805 can be connected to the power supply terminals.
The power supply unit for the IE Switch X-300 power supply must meet NEC Class 2, as
described by the National Electrical Code(r) (ANSI/NFPA 70).
The power of all connected power supply units must total the equivalent of a power
source with limited power (LPS limited power source).
If the device is connected to a redundant power supply (two separate power supplies),
both must meet these requirements.
The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low
voltage (SELV), 24 V DC).
Never operate the device with AC voltage or DC voltage higher than 32 V DC.