Technical data
6.2 Connectors and electrical data
SCALANCE X-300
Compact Operating Instructions, 05/2016, A5E00982643-14
55
Device variant
Transmitter output (optical)
Receiver input
min. [dBm]
max. [dBm]
Sensitivity min. [dBm]
Input power max.
[dBm]
X307-3
-9.5
-4
-17
-3
X307-3LD
-9.5
-3
-21
-3
X308-2 -9.5 -4 -17 -3
X308-2LD
-9.5
-3
-21
-3
X308-2LH
-6
0
-23
-3
X308-2LH+
0
5
-23
-3
X310
-
-
-
-
X310FE
-
-
-
-
X320-1 FE
-19
-14
-32
-3
X320-3LD FE
-15
1)
-8
1)
-34
1)
-3
1)
-19
2)
-14
2)
-32
2)
-3
2)
1)
Fast Ethernet, long distance interface
2)
Fast Ethernet, multimode interface
Note
Exception in the naming of X320-3LD FE
With the X320
-3LD FE IE switch, the key to the name is different. The position -3LD
covers a
total of 3
connectors (1-2) of which only 2 connectors are LD, refer to the explanation below:
Port 21: Multimode
Port 22: LD (long distance, single mode)
Port 23: LD (long distance, single mode)
Note
2 optical interface transceivers possible (X320-3LD FE)
The device is also equipped with 2 optical interface transceivers.
1)
Fast Ethernet, long distance interface
2)
Fast Ethernet, multimode interface
As a result, the electrical data in the technical specifications is divided into two p
arts:
transmitter output optical and receiver input.