EasyManua.ls Logo

Siemens SCALANCE X-300

Siemens SCALANCE X-300
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.7.1.2 SCALANCE X-300 declaration of conformity
You will find the EC Declaration of Conformity for these products on the Internet at the following
address:
SCALANCE X-300 declaration of conformity (
https://
support.industry.siemens.com/cs/ww/en/ps/15296/cert)
1. Click on the entry "SCALANCE X-300 managed" in the navigation panel at the top edge of
the window and from the drop-down list that opens, select the entry for your product group.
2. Select the entry "Certificate" from the "Entry type"drop-down list.
Result: A list of the available certificates is displayed.
11.7.1.3 Overview of XR-300M PoE approvals
Table 11-7 Overview of the approvals
Device Variant c‑UL‑us
Inf. Tech.
Eq.
c‑UL‑us
for Hazard‐
ous Loca‐
tions
1)
c‑UL‑us
Ind. Cont.
Eq.
FM
1)
C‑TICK CE ATEX95
Zone 2
1)
XR324‑4M
PoE
1 x 24 VDC
1 x 100 to
240 VAC
XR324‑4M
PoE TS
1 x 24 VDC
1
For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to the type plate.
11.7.1.4 Mechanical stability in operation
The switch meets the following requirements for mechanical stability:
IEC 60068-2-6 (vibration)
Mounting in the rack: (2-point mounting:)
10 to 58 Hz: 0.075 mm
85 – 150 Hz: 1 g
1 octave/min, 20 sweeps
Individual mounting: (4-point mounting):
5 to 8.51 Hz: 3.5 mm
8.51 – 500 Hz: 1 g
1 octave/min, 20 sweeps
IEC 60068-2-27 (shock)
Mounting in the rack (2-point mounting):
15 g, 11 ms duration, 6 shocks per axis
Certifications and approvals
11.7 Product group XR-300M PoE
SCALANCE X-300
Operating Instructions, 11/2019, A5E01113043-24 289

Table of Contents