Safety instructions
1.4 Security recommendations
SCALANCE X-300
Operating Instructions, 05/2016, A5E01113043-20
19
Safety requirements for installation
According to the IEC 61131-2 standard and therefore in accordance with the EU directive
2006/95/EC (Low Voltage Directive), the devices are "open equipment" and in accordance
with UL/CSA certification, they are an "open type".
To fulfill requirements for safe operation with regard to mechanical stability, flame
retardation, stability, and shock-hazard protection, the following alternative types of
installation are specified:
Installation in a suitable cabinet.
Installation in a suitable enclosure.
Installation in a suitably equipped, enclosed control room.
1.4
Security recommendations
To prevent unauthorized access, note the following security recommendations.
General
You should make regular checks to make sure that the device meets these
recommendations and/or other security guidelines.
Evaluate your plant as a whole in terms of security. Use a cell protection concept with
suitable products.
When confidential zones are used, the internal and external network are disconnected, an
attacker cannot access the data from the outside.
Operate the device only within a protected network area.
Use VPN to encrypt and authenticate communication from and to the devices.
For data transmission via a non-secure network use an encrypted VPN tunnel (IPsec).
For operation of the device in a non-secure infrastructure no product liability will be
accepted.
Separate connections correctly (WBM. Telnet, SSH etc.).
Physical access
Limit physical access to the device to qualified personnel.
The memory card or the C-PLUG contains sensitive data such as certificates, keys etc.
that can be read out and modified.
Lock unused physical ports on the device. Unused ports can be used to gain forbidden
access to the plant.

Table of Contents

Other manuals for Siemens SCALANCE X308-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2 and is the answer not in the manual?

Siemens SCALANCE X308-2 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2
CategorySwitch
LanguageEnglish

Related product manuals