EasyManua.ls Logo

Siemens SIDOOR AT12 - Terminal Circuit Diagram of Control Inputs

Siemens SIDOOR AT12
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A.7 Terminal circuit diagram of control inputs
Elevator door drive AT12
Manual, 02/2012, A2B00086683A-04
43
A.7 Terminal circuit diagram of control inputs
Voage output +24 V DC
120 mA
Elevator controller power supply
GND
NUDGE
CLOSE
OPEN
NUDGE
CLOSE
OPEN
NUDGE
CLOSE
OPEN
Connector with internal power supply Connector with external power supply
Figure A-6 Terminal circuit diagram of control inputs
Nudge = simultaneous activation of the
CLOSE
and
Nudge
commands (effective only in the
closing direction).
Please see chapter Control unit (Page 35) for the permissible voltage values of an external
power supply.
Note
The X202 24 V voltage output mus
t not be connected to an external voltage potential, for
example a higher-level elevator controller.
The X202 connector 2 (minus 24 V) can be connected to the PE.