EasyManuals Logo

Siemens SIMATIC CP 340 User Manual

Siemens SIMATIC CP 340
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Basic Principles of Serial Data Transmission
2.7 Parameterization Data
PtP coupling and configuration of CP 340
78 Manual, 04/2011, A5E00369892-03
Conversion statement
The figure illustrates the structure of a conversion statement schematically.
5HSUHVHQWDWLRQ
W\SH
3UHFLVLRQ:LGWK)ODJ
Figure 2-21 Schematic structure of a conversion statement
Flag
Without = Right-justified output
= Left-justified output
Width
Withou
t
= Output in the standard representation
N = Exactly n characters are output (up to 255 characters are possible); blanks may
be added before (right-justified output) or after (left-justified output).
Precision
Precision is only relevant to display types A, D, F, and R. It is ignored otherwise.
Without = Output in the standard representation (see table below)
.0 = No output of decimal points and decimals in real (R) and floating point (F) format.
.n = Output of decimal point and n (1 to 99) significant decimal positions in real (R)
and floating point (F) display types. In the case of dates (= display types A and
D), precision relates to the number of digits used for the year. Only 2 and 4 are
permitted for dates.
Please note that the precision is always preceded by a period. The period serves to identify it
and separate it from the width.

Table of Contents

Other manuals for Siemens SIMATIC CP 340

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC CP 340 and is the answer not in the manual?

Siemens SIMATIC CP 340 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC CP 340
CategoryComputer Hardware
LanguageEnglish

Related product manuals