EasyManua.ls Logo

Siemens simatic hmi op7 - Page 165

Siemens simatic hmi op7
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C-3
Equipment
Manual OP7, OP17
Release 04/99
OP7 OP17
Interfaces
PP DP DP-12 PP DP DP-12
RS232 1 1 1 2 2 2
TTY 1 1 2 1 2
RS422/485 1 1 1 1
PPI/MPI/
PROFIBUS-DP
(up to 1.5 Mbd)/
RS422/485
1 1 1 1
PPI/MPI/
PROFIBUS-DP
(up to 12 Mbd)/
RS422/485
1 1
OP7 OP17
Ambient conditions
PP DP DP-12 PP DP DP-12
Operating temperature
– vertical installation
– horizontal installation
Transportation, storage
0 °C ... 50 °C
0 °C ... 35 °C
–25 °C ... 70 °C
Relative humidity
– operation
– transportation, storage
95% no dew
95%
Shock resistance
– operation
– transportation, storage
5 g/11 ms
25 g/6 ms
Vibration
– operation
– transportation, storage
0.075 mm(10 Hz ... 58 Hz)
1 g (58 Hz ... 500 Hz)
3.5 mm ( 5 Hz ... 12 Hz)
1 g (12 Hz ... 500 Hz)
Max. pressure difference
(front, rear)
2 hPa
Air pressure
– operation
– transportation, storage
706 ... 1030 hPa
581 ... 1030 hPa