Technical specifications
8.4 Conditions of use
KTP400 Basic, KTP600 Basic, KTP1000 Basic, TP1500 Basic
84 Operating Instructions, 08/2008, A5E01075587-01
Testing mechanical ambient conditions
The following table provides information on the type and scope of tests for mechanical
ambient conditions.
Tested for Test standard Comments
Vibrations Vibration test in accordance
with IEC 60068, part 2–6
(sinusoidal)
Type of vibration:
Transitional rate of the frequency:
1 octave/minute.
10 ≤ f ≤ 58,
Constant amplitude 0.075 mm
58 ≤ f ≤ 150,
Constant acceleration 1 g
Vibration duration:
10 frequency cycles per axis at each of the three
associated vertical axes
Shock Shock test in accordance
with IEC 60068, Part 2 –27
Type of shock: Half-sine
Shock intensity:
Peak value 15 g, duration 11 ms
Direction of impact:
3 shocks in ± direction at each one of the three
associated vertical axes
Climatic ambient conditions
The following table shows the climatic ambient conditions for operation of the HMI device.
Ambient conditions Permitted range Comments
Temperature
Vertical mounting
Mounting at an angle
From 0 to 50° C
From 0 to 40° C
Slope angle max. 35°
Relative humidity 10 to 90 %, without condensation
Atmospheric pressure 1080 to 795 hPa Corresponds to an elevation of
–1,000 to 2,000 m
SO
2
: < 0.5 ppm;
Relative humidity < 60%, no
condensation
Test: 10 cm
3
/m
3
; 10 days Pollutant concentration
H
2
S: < 0.1 ppm;
Relative humidity < 60%, no
condensation
Test: 1 cm
3
/m
3
; 10 days

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC KTP1500 Basic and is the answer not in the manual?

Siemens SIMATIC KTP1500 Basic Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC KTP1500 Basic
CategoryRecording Equipment
LanguageEnglish

Related product manuals