Page #31 background imageLoading...
Page #31 background image
Description of the device
4.6 LED display
SCALANCE WxM766
Operating Instructions, 03/2022, C79000-G8976-C617-03
31
LED
Color
Meaning
L1
Off
Power supply L1 too low.
Green
Power supply L1 is applied.
L2
Off
Power supply L2 too low.
Green
Power supply L2 is applied.
PoE
Off
The device is not supplied using PoE.
Green
The device is supplied using PoE.
Note: If the device is simultaneously connected to 24V voltage
(L1/L2), the power supply to the device is via L1/L2.
P1
Off
There is no connection over the Ethernet interface P1.
Green
There is a connection over the Ethernet interface P1 (link).
Flashing green and
yellow
Data transfer over the Ethernet interface P1.
R1
Off
The WLAN interface 1 is deactivated.
Green
Access Point mode:
The WLAN interface 1 is initialized and ready for operation.
Client mode:
There is a connection over the WLAN interface 1.
Flashing green and
yellow
Data transfer over the WLAN interface 1.
Flashing yellow:
Client mode:
The client is searching for a connection to an access point.
Flashing yellow
Interval:
100 ms on / 100 ms
off
Access Point mode:
With DFS (802.11h), the channel is scanned for one minute for
competing radar signals before the channel can be used for data
traffic.
R2
Off
The functionality of this LED will be configurable for different
applications. It is disabled by default.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W M766 Series and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W M766 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W M766 Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals