Description   
3.2 LED display 
  SCALANCE W774-1/W734-1 
10  Operating Instructions, 09/2015, C79000-G8976-C325-06 
 
L2  Green  Power supply L2. 
Power supply using Power over Ethernet. 
P1 
There is a connection via the first Ethernet interface (Link). 
Green and yel-
low flashing 
Data transfer via the first Ethernet interface. 
P2 
There is a connection via the second Ethernet interface (Link). 
Green and yel-
low flashing 
Data transfer via the second Ethernet interface. 
R1  Green 
SCALANCE W774 in access point mode:
 
The WLAN interface is initialized and ready for operation. 
SCALANCE W774 in client mode or SCALANCE W734:
 
There is a connection via the WLAN interface. 
Green and yel-
low flashing 
Data transfer over the WLAN interface. 
Green  
flashing briefly 
SCALANCE W774 in access point mode:
 
With 802.11h, the channel is scanned for one minute for primary users 
before the channel can be used for data traffic. 
SCALANCE W774 in client mode or SCALANCE W734:
 
The client waits for the MAC address due to the setting "Automatic" for 
the "MAC mode" parameter and is connected to no access point. 
Green 
flashing 3 x 
SCALANCE W774 in client mode or SCALANCE W734:
 
The client waits for the MAC address due to the setting "Automatic" for 
the "MAC mode" parameter and is connected to an access point. 
F 
An error occurred during operation with the device. 
Red 
R1 flashing yel-
low at the same 
A primary user was found on all enabled channels. 
P1 
Flashing yellow  "Flashing" enabled using SIMATIC NET Primary Setup Tool (PST). 
 
 
Note 
Primary user (radar) on all enabled channels 
If the device detects a primary user (for example radar signals) on all enabled channels of 
the WLAN interface, the LED F
 is lit and 
 flashes. No data traffic is then possible for the 
next 30 minutes. After this time, the device runs the scan again and c
hecks whether a 
primary user still exists. If no primary user is detected, data traffic is possible again.
 
The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened 
even by restarting the device.