Security recommendations
SCALANCE W774-1 /W734-1
Operating Instructions, 07/2020, C79000-G8976-C325-14
9
Secure/non-secure protocols and services
Avoid and disable non-secure protocols, for example Telnet and TFTP. For historical
reasons, these protocols are still available, however not intended for secure
applications. Use non-secure protocols on the device with caution.
Check whether use of the following protocols and services is necessary:
Non-authenticated and unencrypted ports
LLDP
Syslog
DHCP options 66/67
TFTP
The following protocols provide secure alternatives:
SNMPv1/v2c SNMPv3
Check whether use of SNMPv1/v2c is necessary. SNMPv1/v2c is classified as
non-secure. Use the option of preventing write access. The product provides you
with suitable setting options.
If SNMP is enabled, change the community names. If no unrestricted access is
necessary, restrict access with SNMP.
Use SNMPv3 in conjunction with passwords.
HTTP HTTPS
Telnet SSH
TFTP SFTP
Use secure protocols when access to the device is not prevented by physical
protection measures.
To prevent unauthorized access to the device or network, take suitable protective
measures against non-secure protocols.
If you require non-secure protocols and services, operate the device only within a
protected network area.
Restrict the services and protocols available to the outside to a minimum.
For the DCP function, enable the "Read Only" mode after commissioning.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W774-1 RJ-45 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W774-1 RJ-45 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W774-1 RJ-45
CategoryWireless Access Point
LanguageEnglish

Related product manuals