9.2.2 100 to 240VAC / 110 to 250VDC device version
The following technical speci󹪝cations apply to the 100 to 240VAC / 110 to 250VDC device
version of the SCALANCE XR322-12.
Technical speci󹪝cations
Connection to Industrial Ethernet
Electrical connectors Quantity 20 2
Connector RJ45 jack RJ45 jack
Transmission speed 10 / 100 / 1000 Mbps 1 / 2.5 / 5 / 10 Gbps
Properties Half/full duplex, MDI‑X pinning
Slots for plug-in transceivers (SFP) Quantity 4
Connector SFP plug-in transceiver
Transmission speed 100 / 1000 Mbps
Slots for plug-in transceiver
(SFP+)
Quantity 8
Connector SFP/ SFP+ plug-in transceiver
Transmission speed 1 / 10 Gbps
Diagnostics interface
Serial interface Quantity 1
Connector USB Type B
Signaling contact
1)
Quantity 1
Design Spring-loaded terminal block, 2-pin
Permitted voltage range 24VDC
Load rating Max. 100 mA
Button Quantity 1
Con󹪝guration interface
Removable data storage medium Quantity 1
Product name Siemens Con󹪝guration and License PLUG (CLP)
Connection to power supply
Power supply
1)
Design IEC plug C14 (AC) DC terminal block, 2-pin
(DC)
Rated voltage 100 to 240VAC 110 to 250VDC
Voltage range 85 to 264VAC 77 to 300VDC
Frequency 50 / 60Hz
Frequency range 50Hz to 60Hz
Fusing 4A / 250V
Properties 6GK5334-3TS00-3AR3 Not redundant Not redundant
6GK5334-3TS00-4AR3 Redundant Redundant
Overvoltage category OVC II
Recommended fusing Fuse max. 20A slow-acting
Class CC, Class RK5
Degree of pollution 2
Current consumption Rated voltage 800mA 800mA
E󹪜ective power loss Rated voltage 99 W
Technical speci󹪝cations
9.2SCALANCE XR322-12
SCALANCE XR-300
Operating Instructions, 03/2023, C79000-G8976-C586-02 95