New functions Customer benefits Where can I find informa
tion?
Synchronization module up to 40 km As of FW version V3.0, a new synchronization
module Sync Module 1 GB FO 40km is avail
able. The synchronization module enables a
distance of up to 40km between the two H-
CPUs via optical fibers. This allows you to use
the S7-1500H redundant system for long tun
nel installations.
S7-1500R/H System Manual
(https://support.industry.
siemens.
com/cs/ww/en/view/10975483
3)
Data block functions As of FW version V3.0, the instructions for the
data block functions are supported:
CREATE_DB (create data block)
READ_DBL (read from data block in the
load memory)
WRIT_DBL (write to data block in load
memory)
DELETE_DB (delete data block)
STEP7 online help
Network management protocol SNMP: A
simple configuration option is now available
for using SNMP services. For new configura
tions, this is disabled by default in accord
ance with "Security-by-Default".
Can be enabled/disabled in the CPU properties.
Community strings can be configured.
Communication Function
Manual
(https://support.industry.
siemens.
com/cs/ww/en/view/59192925
)
Trace: The S7-1500 CPU supports up to 64
configured signals per trace.
Number of configurable signals per trace
extended
Using the Trace and Logic Ana
lyzer Function Function Manu
al
(http://support.automation.
siemens.
com/WW/view/en/64897128)
New functions of the CPU in firmware version V2.9
New functions Customer benefits Where can I find information?
Influence switchover time
of switched S1 devices
As of FW version V2.9, you can influence the
switchover time between disconnection and return of
switched S1 devices after a failure/STOP of the primary
CPU.
This function offers the following advantages:
Optimization of the switchover time between dis
connection and return of switched S1 devices
MRP interconnection The MRP interconnection procedure is an extension of
MRP. MRP interconnection enables the redundant
coupling of 2 or more rings with MRP in PROFINET net
works.
MRP interconnection offers the following advantages:
When setting up redundant network topologies,
there is no limitation to the maximum number of
devices of 50 devices in a ring.
Monitoring of larger topologies with ring redund
ancy.
PROFINET Function Manual
(http://support.automation.siemens.
com/WW/view/en/49948856)
11
Product overview
3.1 New functions
CPU1517H-3PN (6ES7517-3HP00-0AB0)
Equipment Manual, 11/2022, A5E42011886-AD