Mounting and connecting the HMI device
3.1 Preparing for installation
TP700 Comfort Outdoor, TP1500 Comfort Outdoor
18 Compact Operating Instructions, 05/2016, A5E35956909-AC
Degrees of protection
The degrees of protection of the HMI device can only be guaranteed if the following
requirements are met:
Material thickness at the mounting cutout for a protection rating of IP66 or Front face
only Type 4X/Type 12 (Indoor/Outdoor): 2 mm to 6 mm
Permitted deviation from plane at the mounting cutout: ≤ 0.5 mm
This condition must be met for the mounted HMI device.
Permitted surface roughness in the area of the mounting seal: 120 µm (R
z
120)
Compatibility of the mounting cutout to other HMI devices
The mounting cutouts of the following HMI devices are compatible with the mounting cutouts
of the following predecessor devices:
HMI device
Mounting cutout compatible with
TP700 Comfort Outdoor
TP700 Comfort, TP 177B 6", MP 177 6", TP 277 6"
TP1500 Comfort Outdoor TP1500 Comfort
Please note that although the dimensions for the mounting cutout are the same, the device
depth and/or the enclosure front dimensions may differ from the respective dimensions of the
predecessor devices.
Dimensions of the mounting cutout
Width and height should be reversed accordingly when mounting in vertical format.