73Digital Fault Recorder, SIMEAS R/SIMEAS R-PMU, Maintenance Manual
E50417-H1074-C364-A2, Release 11.2009
Fuse 2
2.1 General
The device is protected by a F1 miniature fuse type T 3.15A H 250V, 5 mm x 20 mm. The fuse
is located on the power supply module next to the mains connector.
Caution
If the fuse is damaged, it has interrupted the power supply due to an overload before, in order to
protect the device against damage caused by, e. g., overheating.
If the miniature fuse trips again after it has been replaced, the device has a hardware fault. In
this case, send the device back as described in Chapter 6.