9 Install the new gap 󹪝llers.
Remove the foil from the adhesive surfaces of the
gap 󹪝llers.
Glue the small round gap 󹪝ller onto the encoder
at the position shown.
Glue the new large gap 󹪝ller onto the electron‐
ics board at the position shown.
10
11 Attach the motor cover so that the hole in the cover
lines up with the pin in the motor enclosure .
Carefully ensure that the gap 󹪝llers are at the correct
position and remain in this position.
12 Tighten the cover crosswise using the 4 M5 󹪝xing
screws with the maximum tightening torque 5 Nm.
Description
2.4 Encoder replacement variants
Encoder replacement for SIMOTICS S-1FK2 and S-1FT2
34 Service Manual, 07/2022, A5E52211160B AA