Loading...
Preparing for use
Explosion-protected machines
56100000002002, 01/2016
97
Tandem operation
If you connect two motors in series in "tandem operation", install an insulated
coupling between the motors.
Driving machine
Insulated bearings
Motor
Insulated tachometer fitting
Coupling
Insulated coupling
Figure 4-2 Schematic representation of a tandem drive
NOTICE
Bearing damage
If the coupling between the motors of the tandem drive is not insulated, bearing
currents can cause damage to the drive-end bearings of both motors.
Use an insulated coupling to link the motors.
4.7.4 Operation with insulated coupling (EX)
If you connect two motors in series in "tandem operation", fit a coupling between the
motors; this coupling should satisfy the ATEX Directive or the regulations that apply
in the country where the equipment is installed.