Electrical connection
Explosion-protected machines
122 56100000002002, 01/2016
6.6 Final checks
Before closing the terminal box/terminal base of the machine enclosure, check the
following:
Establish the electrical connections in the terminal box in accordance with the
details in the sections above and tighten with the correct torque.
Maintain air clearances between non-insulated parts:
5.5 mm up to 690 V, ≥ 8 mm up to 1000 V.
Avoid protruding wire ends!
In order not to damage the cable insulation, freely arrange the connecting cables.
Connect the machine corresponding to the specified direction of rotation.
Keep the inside of the terminal box clean and free from trimmed-off ends of wire.
Ensure that all seals and sealing surfaces are undamaged and clean.
Correctly and professionally close unused openings in the terminal boxes.
Before closing the terminal box, check that
the air clearances for explosion-protected machines (with the exception of
machines for Zone 22) between non-insulated parts are maintained: 10 mm to
690 V.
the minimum creepage distance for explosion-protected machines (with the
exception of machines for Zone 22) between non-insulated parts is maintained:
12 mm to 690 V.