Maintenance
Explosion-protected machines
144 56100000002002, 01/2016
Mounting dimension "x" of V rings
Motor
types
Frame size
X
[mm]
All
71
4.5 ±0.6
Standard design
Special design
80 ... 112
6 ±0.8
132 ... 160
7 ±1
1LA
1MA6
180 ... 200
1FP1
180 ... 200
11 ±1
1LG
1MA622
1LE
1MB1
180 ... 225
11 ±1
1LG
1MA6
1LE
1MB1
250 ... 315
13.5 ±1.2
9.7.2 Mounting fans
Take care not to damage the snapping mechanisms on fans that are equipped
with these.
To ensure this, the fans should be heated to a temperature of approximately
50 °C around the area of the hub.
If any damage is caused, request new parts.
9.7.3 Reassembly: Miscellaneous information
Position all rating and supplementary plates as in the original state.
Where relevant, fix electric cables.
Check the tightening torques of all screws, as well as those of screws that have
not been released.