5.1 Wiring
SIMOTION C
106 Operating Instructions, 02/2012
Setpoint assignment
The assignment of the setpoints for axes 1 to 4 is fixed.
Setpoint output signals (X2) for drives with analog interface:
SW1, BS1, RF1.1, RF1.2 for axis 1
SW2, BS2, RF2.1, RF2.2 for axis 2
SW3, BS3, RF3.1, RF3.2 for axis 3
SW4, BS4, RF4.1, RF4.2 for axis 4
Note
When using the drive interface for standard outputs (C240 only), proceed as described in
chapter Onboard drive interface (C230-2, C240) (Page 45). Wire the free ends of the
con
necting cable according to your application.